Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45.081
Filter
1.
J. optom. (Internet) ; 17(2): [100488], Abr-Jun, 2024. tab, graf
Article in English | IBECS | ID: ibc-231623

ABSTRACT

Purpose: As ocular dryness and glaucoma are more prevalent with increasing age, understanding how the tear film affects tonometry is important. The present study aims to understand the impact that changes in the tear film have on intraocular pressure (IOP), corneal hysteresis, and corneal resistance factor measurements. Methods: Cross-sectional research was conducted and 37 patients were assessed. The tear film lipid layer and the non-invasive break-up time (NIBUT) were evaluated using the Tearscope Plus (Keeler, Windsor, UK). Dry eye symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. IOP was measured using rebound tonometry and the Ocular Response Analyzer (ORA, Reichert). Corneal biomechanical properties were measured using ORA. Results: It was found that an increase in the IOP measured with the iCare was directly correlated with the subclass that evaluated symptomatology associated with environmental factors (r = 0.414, p<0.05, Spearman). Goldmann-correlated IOP (IOPg) and Corneal-compensated IOP (IOPcc) values were statistically significantly different between the various interferometric patterns (p<0.05). It was also found that an increase in the corneal biomechanical properties measured with ORA was directly correlated with the overall scores obtained when using the OSDI and some of its subclasses. Conclusions: Tear film interferometric patterns were shown to have some impact on the IOP measured using ORA. The IOP measured with iCare seems to be related to the symptomatology obtained from OSDI. Corneal biomechanical properties were related to the OSDI total score and some of its subclasses. An increase in symptomatology was associated with an increase in the measured biomechanical properties of the cornea.(AU)


Subject(s)
Humans , Male , Female , Optometry , Lacrimal Apparatus , Vision, Ocular , Dry Eye Syndromes , Glaucoma , Intraocular Pressure
2.
J Biomed Opt ; 29(3): 037003, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38560532

ABSTRACT

Significance: Glaucoma, a leading cause of global blindness, disproportionately affects low-income regions due to expensive diagnostic methods. Affordable intraocular pressure (IOP) measurement is crucial for early detection, especially in low- and middle-income countries. Aim: We developed a remote photonic IOP biomonitoring method by deep learning of the speckle patterns reflected from an eye sclera stimulated by a sound source. We aimed to achieve precise IOP measurements. Approach: IOP was artificially raised in 24 pig eyeballs, considered similar to human eyes, to apply our biomonitoring method. By deep learning of the speckle pattern videos, we analyzed the data for accurate IOP determination. Results: Our method demonstrated the possibility of high-precision IOP measurements. Deep learning effectively analyzed the speckle patterns, enabling accurate IOP determination, with the potential for global use. Conclusions: The novel, affordable, and accurate remote photonic IOP biomonitoring method for glaucoma diagnosis, tested on pig eyes, shows promising results. Leveraging deep learning and speckle pattern analysis, together with the development of a prototype for human eyes testing, could enhance diagnosis and management, particularly in resource-constrained settings worldwide.


Subject(s)
Deep Learning , Glaucoma , Humans , Animals , Swine , Intraocular Pressure , Glaucoma/diagnostic imaging , Tonometry, Ocular , Sclera
3.
Arq Bras Oftalmol ; 87(6): e2021, 2024.
Article in English | MEDLINE | ID: mdl-38597522

ABSTRACT

Implantation of glaucoma drainage devices is a valuable therapeutic option, particularly in children with glaucoma refractory to primary surgical treatment. Glaucoma drainage devices are typically used when conjunctival scarring hampers filtration surgery or prior angle procedures are not effective in controlling intraocular pressure. Despite known complications, the use of glaucoma drainage devices in children has increased in recent years, even as the primary surgical option. In this review, we evaluate the results of recent studies involving the implantation of glaucoma drainage devices in children, discussing new advances, and comparing the success rates and complications of different devices.


Subject(s)
Conjunctival Diseases , Glaucoma Drainage Implants , Glaucoma , Child , Humans , Glaucoma Drainage Implants/adverse effects , Glaucoma/surgery , Intraocular Pressure , Prosthesis Implantation/methods , Retrospective Studies , Treatment Outcome
4.
Sci Rep ; 14(1): 8160, 2024 04 08.
Article in English | MEDLINE | ID: mdl-38589521

ABSTRACT

To analyze the changing trend of CH and CRF values under different influencing factors in T2DM patients. A total of 650 patients with T2DM were included. We discovered that the course of T2DM, smoking history, BMI, and FBG, DR, HbA1c, TC, TG, and LDL-C levels were common risk factors for T2DM, while HDL-C levels were a protective factor. Analyzing the CH and CRF values according to the course of diabetes, we discovered that as T2DM continued to persist, the values of CH and CRF gradually decreased. Moreover, with the increase in FBG levels and the accumulation of HbA1c, the values of CH and CRF gradually decreased. In addition, in patients with HbA1c (%) > 12, the values of CH and CRF decreased the most, falling by 1.85 ± 0.33 mmHg and 1.28 ± 0.69 mmHg, respectively. Compared with the non-DR group, the CH and CRF values gradually decreased in the mild-NPDR, moderate-NPDR, severe-NPDR and PDR groups, with the lowest CH and CRF values in the PDR group. In patients with T2DM, early measurement of corneal biomechanical properties to evaluate the change trend of CH and CRF values in different situations will help to identify and prevent diabetic keratopathy in a timely manner.


Subject(s)
Cornea , Diabetes Mellitus, Type 2 , Humans , Glycated Hemoglobin , Biomechanical Phenomena , Intraocular Pressure , Elasticity , Tonometry, Ocular
5.
Article in Russian | MEDLINE | ID: mdl-38640221

ABSTRACT

According to world forecasting, the number of patients with glaucoma all over the world will reach 111.8 million up to 2040 . The percentage of primary open-angle glaucoma is 2.34% and primary closed-angle glaucoma is 0.73%. According to mathematical forecast, further increasing of common and primary morbidity is expected. The retrospective analysis of patient records of the Department of Eye Microsurgery № 2 of the National Hospital of the Ministry of Health of the Kyrgyz Republic was carried out. It is established that among total number of treated patients with glaucoma, no significant difference in rate of cases of closed-angle (53,7±1,7) and open-angle forms (46,3±1,7) was established. In most cases, open-angle glaucoma was diagnosed in age group of 60-79 years and closed-angle glaucoma in age group of 50-79 years. The women are reliably more often suffer of glaucoma. The majority of patients had stage III (42,3±2,5), stage II (31,8±2,4) and stage I (22,2±2,1). At all stages, women more often had glaucoma with the exception of stage III and IV that were diagnosed with same rate were diagnosed in patients of both sexes. Unfortunately, there were isolated cases of open-angle glaucoma at young age. The results of the study dictate importance of prevention, early diagnostic, treatment and rehabilitation of ophthalmologic patients.


Subject(s)
Glaucoma, Angle-Closure , Glaucoma, Open-Angle , Glaucoma , Male , Humans , Female , Middle Aged , Aged , Glaucoma, Open-Angle/diagnosis , Glaucoma, Open-Angle/epidemiology , Glaucoma, Angle-Closure/diagnosis , Retrospective Studies , Kyrgyzstan , Intraocular Pressure , Glaucoma/epidemiology
6.
Lasers Surg Med ; 56(4): 382-391, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38570914

ABSTRACT

BACKGROUND AND OBJECTIVES: Femtosecond laser trabeculotomy (FLT) creates aqueous humor outflow channels through the trabecular meshwork (TM) and is an emerging noninvasive treatment for open-angle glaucoma. The purpose of this study is to investigate the effect of pulse energy on outflow channel creation during FLT. MATERIALS AND METHODS: An FLT laser (ViaLase Inc.) was used to create outflow channels through the TM (500 µm wide by 200 µm high) in human cadaver eyes using pulse energies of 10, 15, and 20 µJ. Following treatment, tissues were fixed in 4% paraformaldehyde. The channels were imaged using optical coherence tomography (OCT) and assessed as full thickness, partial thickness, or not observable. RESULTS: Pulse energies of 15 and 20 µJ had a 100% success rate in creating full-thickness FLT channels as imaged by OCT. A pulse energy of 10 µJ resulted in no channels (n = 6), a partial-thickness channel (n = 2), and a full-thickness FLT channel (n = 2). There was a statistically significant difference in cutting widths between the 10 and 15 µJ groups (p < 0.0001), as well as between the 10 and 20 µJ groups (p < 0.0001). However, there was no statistically significant difference between the 15 and 20 µJ groups (p = 0.416). CONCLUSIONS: Fifteen microjoules is an adequate pulse energy to reliably create aqueous humor outflow channels during FLT in human cadaver eyes. OCT is a valuable tool when evaluating FLT.


Subject(s)
Glaucoma, Open-Angle , Trabeculectomy , Humans , Trabeculectomy/methods , Glaucoma, Open-Angle/surgery , Intraocular Pressure , Lasers , Cadaver
7.
Invest Ophthalmol Vis Sci ; 65(4): 9, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38568619

ABSTRACT

Purpose: Intravitreal injection of drugs is commonly used for treatment of chorioretinal ocular pathologies, such as age-related macular degeneration. Injection causes a transient increase in the intraocular volume and, consequently, of the intraocular pressure (IOP). The aim of this work is to investigate how intravitreal flow patterns generated during the post-injection eye deflation influence the transport and distribution of the injected drug. Methods: We present mathematical and computational models of fluid motion and mass transport in the vitreous chamber during the transient phase after injection, including the previously unexplored effects of globe deflation as ocular volume decreases. Results: During eye globe deflation, significant fluid velocities are generated within the vitreous chamber, which can possibly contribute to drug transport. Pressure variations within the eye globe are small compared to IOP. Conclusions: Even if significant fluid velocities are generated in the vitreous chamber after drug injection, these are found to have negligible overall effect on drug distribution.


Subject(s)
Anterior Eye Segment , Intraocular Pressure , Intravitreal Injections , Biological Transport , Models, Theoretical
8.
Sci Rep ; 14(1): 8000, 2024 04 05.
Article in English | MEDLINE | ID: mdl-38580736

ABSTRACT

We investigated optic nerve head factors associated with initial parafoveal scotoma (IPFS) in primary open-angle glaucoma. Eighty (80) patients with an IPFS and 84 patients with an initial nasal step (INS) were compared. Central retinal vascular trunk (CRVT) deviation from the Bruch's membrane opening (BMO) center was measured as a surrogate of lamina cribrosa (LC)/BMO offset, and its obliqueness was defined as the absolute value of angular deviation from the fovea-BMO axis. Proximity of retinal nerve fiber layer defect (RNFLD) was defined as the angular deviation of the inner RNFLD margin from the fovea-BMO axis. Microvasculature dropout (MvD) was defined as a focal sectoral capillary dropout with no visible microvascular network identified in the choroidal layer. Factors associated with IPFS, as compared with INS, were assessed using logistic regression analyses and conditional inference tree analysis. The IPFS group had more oblique CRVT offset (P < 0.001), RNFLD closer to the fovea (P < 0.001), more MvD (P < 0.001), and more LC defects (P < 0.001) compared to the INS group. In logistic regression analyses, obliqueness of CRVT offset (P = 0.002), RNFLD proximity (P < 0.001), and MvD (P = 0.001) were significant factors influencing the presence of IPFS. Conditional inference tree analysis showed that RNFLD closer to the fovea (P < 0.001) in the upper level, more oblique CRVT offset (P = 0.013) and presence of MvD (P = 0.001) in the lower level were associated with the probability of having IPFS. IPFS was associated with closer RNFLD location to the fovea when assessed from the BMO. Oblique LC/BMO offset may not only mask RNFLD proximity to the fovea due to a deviated funduscopic disc appearance, but also potentiate IPFS via focal LC defect and MvD.


Subject(s)
Glaucoma, Open-Angle , Optic Disk , Retinal Diseases , Humans , Optic Disk/blood supply , Scotoma/complications , Glaucoma, Open-Angle/complications , Visual Fields , Intraocular Pressure , Vision Disorders/complications , Retinal Diseases/complications , Tomography, Optical Coherence
9.
Int J Mol Sci ; 25(7)2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38612500

ABSTRACT

Increased intraocular pressure (IOP) is the most important risk factor for glaucoma. The role of IOP fluctuation, independently from elevated IOP, has not yet been confirmed in glaucoma. We investigated the effects of IOP fluctuation itself on retinal neurodegeneration. Male rats were treated with IOP-lowering eyedrops (brinzolamide and latanoprost) on Mondays and Thursdays (in the irregular instillation group) or daily (in the regular instillation group), and saline was administered daily in the normal control group for 8 weeks. The IOP standard deviation was higher in the irregular instillation group than the regular instillation group or the control group. The degree of oxidative stress, which was analyzed by labeling superoxide, oxidative DNA damage, and nitrotyrosine, was increased in the irregular instillation group. Macroglial activation, expressed by glial fibrillary acidic protein in the optic nerve head and retina, was observed with the irregular instillation of IOP-lowering eyedrops. Microglial activation, as indicated by Iba-1, and the expression of TNF-α did not show a significant difference between the irregular instillation and control groups. Expression of cleaved caspase-3 was upregulated and the number of retinal ganglion cells (RGCs) was decreased in the irregular instillation group. Our findings indicate that IOP fluctuations could be induced by irregular instillation of IOP-lowering eyedrops and this could lead to the degeneration of RGCs, probably through increased oxidative stress and macrogliosis.


Subject(s)
Glaucoma , Intraocular Pressure , Male , Animals , Rats , Retina , Glaucoma/drug therapy , Retinal Ganglion Cells , Ophthalmic Solutions
10.
J Transl Med ; 22(1): 355, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622600

ABSTRACT

BACKGROUND: Glaucoma is a leading cause of worldwide irreversible blindness. Considerable uncertainty remains regarding the association between a variety of phenotypes and the genetic risk of glaucoma, as well as the impact they exert on the glaucoma development. METHODS: We investigated the associations of genetic liability for primary open angle glaucoma (POAG) with a wide range of potential risk factors and to assess its impact on the risk of incident glaucoma. The phenome-wide association study (PheWAS) approach was applied to determine the association of POAG polygenic risk score (PRS) with a wide range of phenotypes in 377, 852 participants from the UK Biobank study and 43,623 participants from the Penn Medicine Biobank study, all of European ancestry. Participants were stratified into four risk tiers: low, intermediate, high, and very high-risk. Cox proportional hazard models assessed the relationship of POAG PRS and ocular factors with new glaucoma events. RESULTS: In both discovery and replication set in the PheWAS, a higher genetic predisposition to POAG was specifically correlated with ocular disease phenotypes. The POAG PRS exhibited correlations with low corneal hysteresis, refractive error, and ocular hypertension, demonstrating a strong association with the onset of glaucoma. Individuals carrying a high genetic burden exhibited a 9.20-fold, 11.88-fold, and 28.85-fold increase in glaucoma incidence when associated with low corneal hysteresis, high myopia, and elevated intraocular pressure, respectively. CONCLUSION: Genetic susceptibility to POAG primarily influences ocular conditions, with limited systemic associations. Notably, the baseline polygenic risk for POAG robustly associates with new glaucoma events, revealing a large combined effect of genetic and ocular risk factors on glaucoma incidents.


Subject(s)
Glaucoma, Open-Angle , Humans , Glaucoma, Open-Angle/genetics , Glaucoma, Open-Angle/epidemiology , Intraocular Pressure , 60488 , Biological Specimen Banks , Genome-Wide Association Study , Genetic Predisposition to Disease , Risk Factors
11.
Int Ophthalmol ; 44(1): 182, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38625418

ABSTRACT

BACKGROUND/AIMS: This work aimed to investigate changes in optic nerve head (ONH) morphometry based on Bruch membrane opening in children with extensive nocturnal intraocular pressure (IOP) elevations. METHODS: The course of Bruch membrane opening-based optic nerve head (ONH) morphometry was analysed in thirty-two patients younger than 18 years with evaluable SD-OCT examinations of the ONH and nocturnal posture-dependent IOP elevation above 25 mmHg. Longitudinal changes in neuroretinal rim tissue, as measured by Bruch Membrane opening minimum rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (RNFL) thickness, were assessed. RESULTS: One year after the 24 h IOP measurement, global BMO-MRW (- 1.61 ± 16.8 µm, n.s.; p = 0.611) and RNFL (+ 0.64 ± 3.17 µm; n.s.; p = 0.292) measurements were not significantly different from the baseline. No significant BMO-MRW reduction (- 3.91 ± 24.3 µm; n.s. p = 0.458) or deviation in RNFL thickness (+ 1.10 ± 3.52 µm) was observed at the four-year follow-up. Absolute IOP values measured in the supine position did not correlate with changes in global BMO-MRW or RNFL thickness. CONCLUSION: Posture-dependent IOP elevations do not seem to influence retinal nerve fibre layer thickness or Bruch membrane opening-based morphometric data in childhood.


Subject(s)
Eye Diseases , Optic Disk , Child , Humans , Intraocular Pressure , Tonometry, Ocular , Retina , Posture
12.
Sci Rep ; 14(1): 8279, 2024 04 09.
Article in English | MEDLINE | ID: mdl-38594403

ABSTRACT

The aim of the study was to compare the anterior segment parameters after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes. We conducted a prospective comparative study of 36 eyes (PEX group), 16 eyes (PEXG group) and 46 eyes (control group) of 98 patients after phacoemulsification with intraocular lens implantation. Before surgery, 1 week, 1 month and 3 months postoperatively, anterior chamber parameters were evaluated by swept source anterior segment optical coherence tomography (AS-OCT). Anterior chamber depth (ACD), angle opening distance (AOD500/750), trabecular-iris space area (TISA500/750), trabecular-iris angle (TIA500/750) and lens vault (LV) were assessed at each study visit. Preoperatively, ACD, AOD500/750 and TISA500/750 were significantly smaller, while LV was significantly greater in PEX and PEXG eyes than in controls. 3 months postoperatively all irido-corneal parameters and ACD were significantly greater in all study groups without intergroup differences. ACD and LV significantly increased in PEX group between 1 and 3 months after surgery while being stable in control group. Relative increases in ACD, AOD500, TISA750, TIA500/750 were significantly higher in PEX and PEXG groups than in controls. Our study finds that ACD and iridocorneal parameters in AS-OCT demonstrated significantly greater relative increases 3 months after phacoemulsification in PEX and PEXG groups than in control eyes. Significantly greater deepening of anterior chamber and opening of the irido-corneal angle may be a reason for different refractive outcomes and IOP control in patients with PEX and PEXG after routine cataract surgery.


Subject(s)
Cataract , Exfoliation Syndrome , Humans , Tomography, Optical Coherence/methods , Exfoliation Syndrome/diagnostic imaging , Prospective Studies , Intraocular Pressure , Anterior Chamber , Anterior Eye Segment/diagnostic imaging
13.
BMC Ophthalmol ; 24(1): 168, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622519

ABSTRACT

INTRODUCTION: Corneal biomechanics has been implicated in a variety of ocular diseases. The purpose of this study was to evaluate the relationship between the glaucoma and corneal biomechanical properties, and exploring the value of corneal biomechanics in the diagnosis and follow-up of glaucoma diseases. METHODS: We searched studies in PubMed, EMBASE, Web of Science and clinicaltrials.gov., as of October 8, 2022. Only English studies were included, without publication time limit. We also searched the reference lists of published reviews. This meta-analysis was conducted with random-effects models, we used mean difference(MD) to evaluate the outcome, and the heterogeneity was assessed with the I2 statistic. Subgroup analyses were performed under the appearance of high heterogeneity. We used 11 items to describe the characteristics of included studies, publication bias was performed through the Egger's test. The quality assessment were evaluated by Newcastle-Ottawa Scale(NOS) items. RESULTS: A total of 27 eligible studies were identified for data synthesis and assessment. The result of meta-analysis showed that in the comparison of included indicators, the corneal biomechanics values of glaucoma patients were statistically lower than those of normal subjects in a similar age range. The covered indicators included central corneal thickness(CCT) (MD = -8.34, 95% CI: [-11.74, -4.94]; P < 0.001), corneal hysteresis(CH)(MD = -1.54, 95% CI: [-1.88, -1.20]; P < 0.001), corneal resistance factor(CRF)( MD = -0.82, 95% CI: [-1.21, -0.44]; P < 0.001), and intraocular pressure(IOP)( corneal-compensated intraocular pressure (IOPcc): MD = 2.45, 95% CI: [1.51, 3.38]; P < 0.001); Goldmann-correlated intraocular pressure (IOPg): MD = 1.30, 95% CI: [0.41, 2.20]; P = 0.004), they all showed statistical difference. While the value of axial length(AL) did not show statistically different(MD = 0.13, 95% CI: [-0.24, 0.50]; P = 0.48). CONCLUSION: Corneal biomechanics are associated with glaucoma. The findings can be useful for the design of glaucoma screening, treatment and prognosis.


Subject(s)
Glaucoma , Humans , Biomechanical Phenomena , Glaucoma/diagnosis , Intraocular Pressure , Cornea , Tonometry, Ocular
14.
BMJ Open Ophthalmol ; 9(1)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38626931

ABSTRACT

OBJECTIVE: To investigate the characteristics of beta parapapillary atrophy (ß-PPA) in patients with primary angle-closure suspect (PACS). METHODS AND ANALYSIS: In total, 215 and 259 eyes with PACS and non-PACS (NPACS), respectively, were enrolled in this observational, cross-sectional study. Stereoscopic fundus and optical coherence tomography images were used to characterise ß-PPA; the former was also used to measure the major ß-PPA parameters. Univariate and multiple logistic regression analyses were used to identify the factors correlated with the presence of ß-PPA and with ß-PPA parameters. RESULTS: The ß-PPA occurrence rates were 48.80% and 44.40% in the PACS and NPACS groups, respectively, with no significant difference between groups. Compared with that in the NPACS group, the ß-PPA area was significantly larger (p=0.005) in the PACS group, but the angular extent and maximum radial length did not differ between groups (p=0.110 and 0.657, respectively) after adjusting for age and axial length. The presence of ß-PPA was associated with older age (OR 1.057, 95% CI 1.028 to 1.088, p<0.001) and larger disc area (OR 1.716, 95% CI 1.170 to 2.517, p=0.006). A larger ß-PPA area was associated with older age (p=0.014), greater vertical cup-to-disc ratio (p=0.028), larger disc area (p<0.001) and PACS diagnosis (p=0.035). CONCLUSION: 48.80% of participants with PACS had ß-PPA, which is slightly larger than NPACS. The area of ß-PPA was larger in PACS, while the angular extent and maximum radial length did not differ between groups.


Subject(s)
Eye Diseases, Hereditary , Glaucoma, Open-Angle , Optic Atrophy , Optic Disk , Humans , Optic Disk/pathology , Glaucoma, Open-Angle/complications , Optic Atrophy/complications , Cross-Sectional Studies , Intraocular Pressure , Visual Fields , Atrophy/complications
15.
BMJ Open Ophthalmol ; 9(1)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38626932

ABSTRACT

BACKGROUND/AIMS: This study aimed to investigate and compare the efficacy and safety of first-line and second-line selective laser trabeculoplasty (SLT) in Japanese patients with normal-tension glaucoma (NTG). METHODS: 100 patients with NTG were enrolled in this study. Patients were treated with SLT as a first-line or second-line treatment for NTG. Main outcome measures were intraocular pressure (IOP) reduction rate, outflow pressure improvement rate (ΔOP), success rate at 1 year and complications. Success was defined as ΔOP≥20% (criterion A) or an IOP reduction ≥20% (criterion B) without additional IOP-lowering eye-drops, repeat SLT or additional glaucoma surgeries. The incidence of transient IOP spike (>5 mm Hg from the pretreatment IOP), conjunctival hyperaemia, inflammation in the anterior chamber and visual impairment due to SLT were assessed. RESULTS: A total of 99 patients (99 eyes) were initially enrolled in this study, including 74 eyes assigned to the first-line SLT group and 25 eyes to the second-line SLT group. The mean IOP of 16.3±2.1 mm Hg before SLT decreased by 17.1%±9.5% to 13.4±1.9 mm Hg at 12 months after SLT in the first-line group (p<0.001), and the mean IOP of 15.4±1.5 mm Hg before SLT decreased by 12.7%±9.7% to 13.2±2.0 mm Hg at 12 months after SLT (p=0.005) in the second-line group. Both groups showed significant reductions in IOP. Higher pre-SLT IOP and thinner central corneal thickness were associated with greater IOP reduction. The success rate at 1 year was higher in the first-line compared with the second-line group, with lower pretreatment IOP and the use of IOP-lowering medication before SLT being associated with treatment failure. Most post-treatment complications were minor and transient. CONCLUSIONS: SLT may be an effective and safe treatment option for NTG, as either a first-line or second-line treatment. TRIAL REGISTRATION NUMBER: The study was registered in the UMIN-CTR (UMIN Test ID: UMIN R000044059).


Subject(s)
Glaucoma , Lasers, Solid-State , Low Tension Glaucoma , Ocular Hypotension , Trabeculectomy , Humans , Trabeculectomy/adverse effects , Intraocular Pressure , Low Tension Glaucoma/surgery , Glaucoma/surgery , Ocular Hypotension/surgery , Anterior Chamber , Lasers, Solid-State/therapeutic use , Cohort Studies
16.
Sci Rep ; 14(1): 8889, 2024 04 17.
Article in English | MEDLINE | ID: mdl-38632299

ABSTRACT

We aimed to investigate the changes in cupping in chiasmal lesion optic neuropathy (chON) compared to baseline optic disc and glaucoma. We used a novel study design to enroll patients who had fundus photographs incidentally taken during routine health check-ups prior to the onset of optic neuropathy. In 31 eyes (21 patients) with chON and 33 eyes (30 patients) with glaucoma, we investigated the change in cup-to-disc (C/D) area from the baseline to overt cupping using flicker analysis. Compared to the baseline, 23 eyes (74.2%) had increased cup size and 3 (9.7%) had vascular configuration changes in the chONgroup; in contrast, all glaucoma eyes exhibited changes in cup size and vascular configuration. The increase in C/D area ratio was significantly smaller in chON (0.04 ± 0.04) compared to glaucoma (0.10 ± 0.04, P < 0.001); the minimum residual neuroretinal rim width showed a more pronounced difference (29.7 ± 8.2% vs 7.1 ± 3.9%, P < 0.001). The changes distributed predominantly towards the nasal direction in chON, contrasting the changes to the arcuate fibers in glaucoma. In conclusion, our results provide the first longitudinal evidence of true pathological cupping in chONcompared to photographically disease-free baseline. The marked difference in the residual minimum rim width reaffirms the importance of rim obliteration in the differential diagnosis between the two diseases.


Subject(s)
Glaucoma , Optic Disk , Optic Nerve Diseases , Humans , Optic Disk/pathology , Glaucoma/pathology , Optic Nerve Diseases/pathology , Optic Chiasm/pathology , Fundus Oculi , Intraocular Pressure
17.
Sci Rep ; 14(1): 8972, 2024 04 18.
Article in English | MEDLINE | ID: mdl-38637538

ABSTRACT

Glaucoma, particularly primary open-angle glaucoma (POAG), poses a significant global health concern. Distinguished by intraocular pressure (IOP), POAG encompasses high-tension glaucoma (HTG) and normal-tension glaucoma (NTG). Apolipoprotein E (APOE) is a multifaceted protein with roles in lipid metabolism, neurobiology, and neurodegenerative diseases. However, controversies persist regarding the impact of APOE single-nucleotide polymorphisms (SNPs) on open-angle glaucoma and NTG. This study aimed to identify APOE-specific SNPs influencing NTG risk. A cohort of 178 patients with NTG recruited from Uijeongbu St. Mary's Hospital and 32,858 individuals from the Korean Genome and Epidemiology Study (KoGES) cohort were included in the analysis. Genotype and haplotype analyses were performed on three promoter SNPs (rs449647, rs769446, and rs405509) and two exonic SNPs (rs429358 and rs7412) located on chromosome 19. Among the five SNPs, rs769446 genotypes exhibited significant differences between cases and controls. The minor allele C of rs769446 emerged as a protective factor against NTG. Furthermore, haplotype analysis of the five SNPs revealed that the A-T-G-T-T haplotype was a statistically significant risk factor for NTG. This study indicated an association between APOE promoter SNPs and NTG in the Korean population. Further studies are required to understand how APOE promoter SNPs contribute to NTG pathogenesis.


Subject(s)
Glaucoma, Open-Angle , Low Tension Glaucoma , Humans , Apolipoproteins E/genetics , Genotype , Glaucoma, Open-Angle/genetics , Intraocular Pressure , Low Tension Glaucoma/genetics , Polymorphism, Single Nucleotide , Republic of Korea/epidemiology
18.
Turk J Ophthalmol ; 54(2): 83-89, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38645613

ABSTRACT

Objectives: To review the current literature related to the correlation between translaminar pressure difference (TLPD) and glaucoma. Materials and Methods: In this article, we conducted a literature review using MEDLINE via PubMed, Cochrane Eyes and Vision, and Google Scholar from 01/01/2010 to 31/12/2022. Search terms included "glaucoma", "intraocular pressure", "translaminar cribrosa pressure gradient/difference", "intracranial pressure", and "cerebrospinal fluid pressure". Of 471 results, 8 articles were selected for the meta-analysis. Results: Our meta-analysis demonstrated significantly higher intraocular pressure, lower cerebrospinal fluid pressure (CSFp), and greater TLPD in high-tension and normal-tension glaucoma groups compared to healthy groups. Conclusion: The differences in CSFp and TLPD between glaucoma and healthy people detected in current studies suggests a potential relationship between TLPD and glaucoma.


Subject(s)
Intraocular Pressure , Optic Nerve Diseases , Humans , Intraocular Pressure/physiology , Optic Nerve Diseases/diagnosis , Optic Nerve Diseases/etiology , Optic Nerve Diseases/physiopathology , Cerebrospinal Fluid Pressure/physiology , Glaucoma/physiopathology , Tonometry, Ocular , Low Tension Glaucoma/physiopathology , Low Tension Glaucoma/diagnosis
20.
Klin Monbl Augenheilkd ; 241(4): 347-354, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38653289

ABSTRACT

BACKGROUND: Various yoga positions may have an unfavorable impact on intraocular pressure (IOP) and may therefore be seen as a potential risk factor for the progression of glaucoma. The new "iCare HOME2" is a handheld self-tonometer for IOP measurements outside clinical settings. This is the first study to evaluate the immediate effect of common yoga postures on the IOP of healthy and glaucomatous eyes using the "iCare HOME2" self-tonometer and to compare the time of IOP recovery in both groups. METHODS: This is a single-center, prospective, observational study including 25 healthy and 25 glaucoma patients performing the following yoga positions: "legs up" (Viparita Karani), "bend over" (Uttanasana), "plough pose" (Halasana), and the "down face dog" (Adho Mukha Svanasana) for 90 s each, with a 2-min break in between. IOP was measured with the "iCare HOME2" before, during, and after each position. RESULTS: IOP significantly increased in all eyes in all positions (p < 0.05), showing no statistically significant difference between healthy or glaucomatous eyes (p > 0.05). The mean rise in IOP in healthy subjects was 1.6 mmHg (SD 1.42; p = 0.037), 14.4 mmHg (SD 4.48; p < 0.001), 7.5 mmHg (SD 4.21; p < 0.001), and 16.5 mmHg (SD 3.71; p < 0.001), whereas in glaucoma patients, IOP rose by 2.8 mmHg (SD 2.8; p = 0.017), 11.6 mmHg (SD 3.86; p < 0.001), 6.0 mmHg (SD 2.24; p < 0.001), and 15.1 mmHg (SD 4.44; p < 0.001) during the above listed yoga positions, repsectively. The highest increase in IOP was seen in the down face position, reaching mean IOP values above 31 mmHg in both study groups. IOP elevation was observed immediately after assuming the yoga position, with no significant change during the following 90 s of holding each pose (p > 0.05). All IOP values returned to baseline level in all individuals, with no significant difference between healthy and glaucoma participants. CONCLUSION: Our data show that common yoga positions can lead to an acute IOP elevation of up to 31 mmHg in healthy as well as glaucoma eyes, with higher IOP values during head-down positions. Given that IOP peaks are a major risk factor for glaucomatous optic neuropathy, we generally advise glaucoma patients to carefully choose their yoga exercises. If and to what extent practicing yoga leads to glaucoma progression, however, remains unclear and warrants further research.


Subject(s)
Glaucoma , Intraocular Pressure , Tonometry, Ocular , Yoga , Humans , Intraocular Pressure/physiology , Male , Female , Tonometry, Ocular/methods , Tonometry, Ocular/instrumentation , Middle Aged , Glaucoma/physiopathology , Glaucoma/diagnosis , Glaucoma/therapy , Reproducibility of Results , Adult , Equipment Design , Sensitivity and Specificity , Equipment Failure Analysis , Aged , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...